What does E9 224 mean?
With E9 224, the flue thermostat or the high-limit thermostat has operated. It shows your boiler got hotter than it should, so it shut down. There are several safe checks to try first, but repeat lockouts need an engineer.
Meanings vary a little between models; your manual has the definitive list. In a modern estate home in Walsgrave the condensate pipe commonly runs a long way down an outside wall, and that is the first thing to check on a frosty Coventry morning.
Things you can safely try
1. Look at the pressure gauge
With the heating off and your boiler cool, check the gauge on your boiler fascia. Most boilers want around 1 to 1.5 bar when cold, but your handbook gives the figure for your model. If it reads lower than that, topping up is normally a homeowner job using the filling loop. Open the taps slowly, watch the needle rise, then turn them off fully once you reach the right pressure. If it falls again soon after, water is escaping somewhere and that leak needs finding.
2. Bleed the radiators
Trapped air upsets circulation and can make your boiler overheat. With the heating off and the radiators cool, bleed each radiator with a radiator key, closing the valve as soon as water comes out. Bleeding lowers the pressure, so check the gauge afterwards and top up if needed.
3. Try a single reset
Press the reset button as your handbook describes: on a Greenstar, hold it for around five seconds. Allow a little time for your boiler to try again. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.
Anything behind the casing, and any gas or flue work, must be left to a Gas Safe registered engineer. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999.
Calling an engineer
If E9 224 returns, leave your boiler off: an engineer needs to find out why it is overheating.
Need a hand in Coventry? Call 024 7648 1338 or send us the details and we will call you back. We are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Why it happens
In our experience, and in the manufacturer's own guidance, the usual causes are:
- Sludge or scale in the heat exchanger
- Low pressure or air in the system
- A flue or sensor fault
- Poor circulation from a sticking pump
Related fault codes
- Baxi E110 means overheat / safety thermostat
- Baxi E125 means circulation fault
- Vaillant F.75 means pump or water shortage fault
- All Worcester Bosch codes