What does F.75 mean?
F.75 means your boiler did not detect the expected pressure change when its pump started. Low pressure or air in the system can cause it, as can a failing pump or pressure sensor. Try the simple checks below first; if the code returns, call an engineer.
Codes can differ between models, so check the fault table in your handbook too. If you are in Allesley or Earlsdon, you are well inside our patch.
Things you can safely try
1. Start with the pressure
When the radiators are cold, look at the pressure reading on your boiler. Most boilers want about 1 to 1.5 bar when cold, or whatever figure your manual gives. If it reads below 1 bar, you can typically top it up yourself using the filling loop, a short braided hose or a built-in key under your boiler. Open the valves slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If it falls again soon after, water is escaping somewhere and it needs an engineer to trace it.
2. Let trapped air out of the radiators
Air in the system stops water circulating properly. With the heating off and the radiators cool, open the bleed screw on each radiator until a drop of water shows. Afterwards, check the pressure again, because bleeding lets water out.
3. Use the reset button, once
Use the reset button on the front panel: on Vaillant ecoTEC models you hold it for more than three seconds, and Vaillant suggests no more than three attempts. Wait two or three minutes for it to restart. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.
Do not open your boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and call 0800 111 999.
Calling an engineer
With good pressure and no air, a recurring F.75 points at the pump or sensor, and replacing either is a job for an engineer.
Ring 024 7648 1338 with the code and your boiler's model, or use our enquiry form. We are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Why it happens
In our experience, and in the manufacturer's own guidance, the usual causes are:
- A faulty water pressure sensor
- Air trapped in the system
- Low system pressure
- A pump that is sticking or failing