Baxi · E125

Baxi boiler showing E125

Your Baxi has stopped and the display says E125. This page explains the code, the checks you can safely make and when you need us.

  • Gas Safe registered
  • Written price before work
  • All major boiler makes

Talk to an engineer

Have the boiler make and the code on its display ready when you ring.

024 7648 1338

Open Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

What does E125 mean?

On a Baxi, E125 is a primary circulation fault. Baxi notes it can follow E193, a circulation warning that becomes E125 if it persists. Some causes are simple to rule out, others need a Gas Safe registered engineer.

Meanings vary a little between models; your manual has the definitive list. A bungalow in Finham may still have an older boiler, so we will always tell you honestly whether a repair is worth doing.

Things you can safely try

1. Release air from the radiators

Air pockets interrupt the flow of water around the system. Once the heating has been off for a while, bleed each radiator with a radiator key, closing the valve as soon as water comes out. Afterwards, check the pressure again, because bleeding lets water out.

2. Check the pressure

With the heating off and your boiler cool, read the pressure gauge on the front of your boiler. Most boilers want about 1 to 1.5 bar when cold, but your handbook gives the figure for your model. If it reads under 1 bar, you can typically top it up yourself using the filling loop. Open the valves slowly, watch the needle rise, then shut both valves properly once you reach the right pressure. If it falls again soon after, water is escaping somewhere and that leak needs finding.

3. Use the reset button, once

Follow the reset steps in your manual: the method varies between Baxi ranges, so check your user guide. Wait two or three minutes for it to restart. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.

Do not open your boiler casing, and leave anything on the gas side alone. Smell gas? Get outside and call 0800 111 999.

Calling an engineer

Persistent E125 points to the pump or sludge.

Need a hand in Coventry? Call 024 7648 1338 or send us the details and we will call you back. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Why it happens

Possible causes include:

  • Low pressure
  • Sludge or a blocked filter
  • A pump that is sticking or failing
  • Air in the system

Related fault codes

Questions

Can sludge cause E125?

It can. Sludge and debris restrict flow. An engineer can clean the filter or system.

Can you fix a Baxi boiler in Coventry?

We do. Our Gas Safe registered engineers repair Baxi boilers across CV1 to CV6, including Walsgrave and Finham. Ring 024 7648 1338 and quote E125.

Boiler packed up in Coventry?

Ring with the make and any fault code and we'll take it from there.