Your Vaillant has stopped and the display says F.22. This page explains the code, the checks you can safely make and when you need us.

  • Gas Safe registered
  • Written price before work
  • All major boiler makes

Talk to an engineer

Have the boiler make and the code on its display ready when you ring.

024 7648 1338

Open Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

What does F.22 mean?

On a Vaillant, F.22 is the low water pressure code: your boiler has sensed there is not enough water in the system. Your boiler shuts down to protect itself from running short of water, and it normally disappears by itself once the pressure is restored. Good news: this code is commonly a homeowner fix.

Codes can differ between models, so check the fault table in your handbook too. In a post-war house in Tile Hill the condensate pipe commonly runs a long way down an outside wall, and that is the first thing to check on a frosty Coventry morning.

Things you can safely try

1. Look at the pressure gauge

Once the system has cooled down, look at the pressure reading on your boiler. The majority of boilers want roughly 1 to 1.5 bar when cold, though the manual for your boiler is the final word. If it reads lower than that, you can normally refill it yourself using the filling loop or filling key, which is typically underneath your boiler. Open the taps slowly, watch the needle rise, then close them firmly once you reach the right pressure. If you find yourself topping up every week, water is escaping somewhere and it needs an engineer to trace it.

2. Write the details down

Note the exact code first, plus the make and model from the label on your boiler, and anything unusual you noticed, such as noises or a leak. It means your engineer arrives better prepared.

Never remove your boiler casing or touch the gas valve, gas pipes or flue. If there is a smell of gas, call 0800 111 999 from outside.

Calling an engineer

If you have topped up and it drops again, or F.22 shows even with normal pressure, book an engineer. That points to a leak, a relief valve, the expansion vessel or the pressure sensor itself.

Need a hand in Coventry? Call 024 7648 1338 or send us the details and we will call you back. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Why it happens

Possible causes include:

  • The pressure relief valve letting water out
  • Pressure lost after bleeding radiators
  • An expansion vessel that has lost its air charge
  • A faulty water pressure sensor or its wiring
  • A slow leak at a radiator valve or joint

Related fault codes

Questions

Why does my Vaillant keep showing F.22?

The system is losing water: a weeping valve, the relief valve, a failing expansion vessel or a hidden leak. Topping up treats the symptom, not the cause.

Do you work on Vaillant boilers around Coventry?

We do. Our Gas Safe registered engineers repair Vaillant boilers across CV1 to CV6, including Canley and Radford. Ring 024 7648 1338 and quote F.22.

Boiler packed up in Coventry?

Ring with the make and any fault code and we'll take it from there.