What does EA 229 mean?
EA 229 is not the same as EA 227: here the flame was established and then lost. Condensate and flue problems are frequent causes. Some causes are simple to rule out, others need a Gas Safe registered engineer.
Meanings vary a little between models; your manual has the definitive list. In a 1930s semi in Earlsdon the condensate pipe commonly runs a long way down an outside wall, and that is the first thing to check on a frosty Coventry morning.
Things you can safely try
1. In freezing weather, check the condensate pipe
Condensing boilers drain water through a plastic pipe, typically white or grey, that commonly runs outside to a drain. If it is frozen, your boiler may gurgle and then lock out. Only if the pipe is at ground level and easy to reach, thaw it with a hot water bottle or warm, not boiling, water from a watering can, then reset your boiler. Do not try this at height.
2. Glance at the flue terminal
Have a look from outside to ensure the flue outlet is not obstructed. Do not touch, remove or alter any part of the flue: any damage or blockage is a job for a Gas Safe registered engineer.
3. Ensure gas is reaching the house
Try the gas hob, if you have one. Prepayment customers should check the meter still has credit, since a meter that has run out stops your boiler lighting. Nothing on the gas side of your boiler is a DIY job. If you smell gas, get everyone out and call 0800 111 999.
4. Use the reset button, once
Use the reset button on the front panel: on a Greenstar, hold it for around five seconds. Wait two or three minutes for it to restart. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.
Never remove your boiler casing or touch the gas valve, gas pipes or flue. If there is a smell of gas, call 0800 111 999 from outside.
Calling an engineer
Repeat EA 229 lockouts call for an engineer: the trap sits inside the casing, which is engineer territory.
Ring 024 7648 1338 with the code and your boiler's model, or use our enquiry form. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Why it happens
Possible causes include:
- A frozen or blocked condensate pipe or trap
- A worn flame-sensing electrode
- Strong wind or an obstruction at the flue terminal
- An interruption in the gas supply
Related fault codes
- Worcester Bosch EA 227 means no flame detected at ignition
- Vaillant F.29 means flame loss during operation
- Worcester Bosch D5 means condensate pump fault (floor-standing)