What does EA 227 mean?
On a Worcester Bosch Greenstar, EA with cause code 227 is an ignition lockout: no flame was detected. Worcester's literature points owners to three checks: gas, condensate and flue. Try the simple checks below first; if the code returns, call an engineer.
Meanings vary a little between models; your manual has the definitive list. In a 1930s semi in Earlsdon the condensate pipe commonly runs a long way down an outside wall, and that is the first thing to check on a frosty Coventry morning.
Things you can safely try
1. Check the gas supply
Check that your gas hob works. If you have a prepayment meter, check it has credit and has not tripped, because an empty meter looks exactly like an ignition fault to your boiler. Do not touch any gas pipes or valves on or inside your boiler. If you smell gas, ring 0800 111 999 from outside the property.
2. Check for a frozen condensate pipe
The condensate pipe is the plastic pipe that carries water from your boiler to a drain, commonly outside. If it is frozen, your boiler may gurgle and then lock out. As long as the pipe is low down and safe to reach, thaw it with warm water, never boiling, poured slowly along the pipe, then reset your boiler. Do not try this at height.
3. Check nothing is blocking the flue
From outside, check that nothing obvious is blocking the flue terminal, such as plants, a cover or a nest. Never take apart or adjust the flue yourself: any damage or blockage is a job for a Gas Safe registered engineer.
4. Reset your boiler once
Press the reset button as your handbook describes: on a Greenstar, hold it for around five seconds. Give it several minutes to run through its start-up. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
Never remove your boiler casing or touch the gas valve, gas pipes or flue. Smell gas? Get outside and call 0800 111 999.
Calling an engineer
When the simple checks do not clear it, the electrode, gas pressure and gas valve need testing: those tests involve the gas side of your boiler.
Need a hand in Coventry? Call 024 7648 1338 or send us the details and we will call you back. We are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Why it happens
The manufacturer's fault table and day-to-day experience point to:
- A worn ignition or flame-sensing electrode
- A blocked flue outlet
- Gas off or a prepayment meter with no credit
- A frozen or blocked condensate pipe
- A gas valve or PCB fault
Related fault codes
- Worcester Bosch EA 229 means flame lost during operation
- Vaillant F.28 means ignition failure at start-up
- Baxi E133 means ignition or gas supply fault
- All Worcester Bosch codes
- Boiler breakdown help in Coventry