Vaillant · F.27

Vaillant boiler showing F.27

F.27 has appeared on your Vaillant boiler. Below: the meaning, the likely causes and the point at which to stop and call.

  • Gas Safe registered
  • Written price before work
  • All major boiler makes

Talk to an engineer

Have the boiler make and the code on its display ready when you ring.

024 7648 1338

Open Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

What does F.27 mean?

F.27 means your boiler is detecting a flame signal when no flame should be there. Causes include moisture on the circuit board, a faulty flame monitor or a gas valve that is not sealing. This is not a DIY fault.

Codes can differ between models, so check the fault table in your handbook too. In a bungalow in Finham the condensate pipe commonly runs a long way down an outside wall, and that is the first thing to check on a frosty Coventry morning.

What to do now

1. Get the details ready

Note the exact code first, plus the make and model from the label on your boiler, and what happened just before it appeared. That information helps us diagnose faster.

2. Try a single reset

Follow the reset steps in your manual: on Vaillant ecoTEC models you hold it for more than three seconds, and Vaillant suggests no more than three attempts. Give it several minutes to run through its start-up. A code that returns after one or two resets needs an engineer: repeated resets can hide a fault that needs proper attention.

Anything behind the casing, and any gas or flue work, must be left to a Gas Safe registered engineer. If you smell gas, leave the property and call the National Gas Emergency Service on 0800 111 999.

Calling an engineer

With a gas valve on the list of causes, this needs a Gas Safe registered engineer. If a leak or water has reached your boiler, switch it off at the spur and give us a call.

Need a hand in Coventry? Call 024 7648 1338 or send us the details and we will call you back. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Why it happens

In our experience, and in the manufacturer's own guidance, the usual causes are:

  • A defective flame monitor or PCB
  • Moisture on the electronics
  • A gas solenoid valve that isn't sealing

Related fault codes

Questions

Should I keep resetting F27?

It is best not to. Try once at most. If it returns, leave your boiler off and book a Gas Safe registered engineer.

Do you work on Vaillant boilers around Coventry?

We do. We work on Vaillant boilers all over Coventry, from Wyken to Finham. Ring 024 7648 1338 and quote F.27.